À la maison > produits > instruments de la température >
Endress - Hauser ITEMP TMT82 Temperature Transmitter TMT82 Thermocouple Temperature Sensor Thermal Resistance Sensor

Endress - Hauser ITEMP TMT82 Temperature Transmitter TMT82 Thermocouple Temperature Sensor Thermal Resistance Sensor

TMT82 thermocouple temperature sensor

Endress Hauser temperature transmitter

thermal resistance sensor with warranty

Lieu d'origine:

CHINE

Nom de marque:

E+H

Numéro de modèle:

TMT82

Causez Maintenant
Demandez un devis
Détails du produit
Résolution:
0.01°C
Connexion électrique:
Connecteur M12X1
Matériau mouillé:
Acier inoxydable
Type de pression:
Pression de mesure
Tension:
1 à 5 (V)
Montage:
Direct ou distant
Résistance à l'aspirateur:
10 mbar (0,15 psi)
Précision de référence:
Norme: 0,05% Platine: jusqu'à 0,025%
Matériau de bride:
316SST
Protocole de communication:
CERF
Signal de sortie:
4-20 mA
Application:
À RÉGULATION DE PROCESSUS INDUSTRIEL
Type d'affichage:
Numérique
Type de connexion:
Sans fil
Afficher:
LCD numérique
Mettre en évidence:

TMT82 thermocouple temperature sensor

,

Endress Hauser temperature transmitter

,

thermal resistance sensor with warranty

Conditions de paiement et d'expédition
Quantité de commande min
1 pc
Prix
USD 850
Délai de livraison
7-14 jours
Conditions de paiement
T / t
Capacité d'approvisionnement
100 pc
Description du produit

Stainless Steel TMT82 Temperature and Pressure Transmitter 0~10 bar Capacity


Key Features

Feature

Description

Universal input

Accepts RTDs (2/3/4-wire), thermocouples, resistance, voltage (mV) inputs.

Dual-channel

It can work with two sensors simultaneously: allowing functions like sensor redundancy, mean value, differential measurement, or fallback if one sensor fails.

Output & communication

Standard 4-20 mA output plus HART® protocol (latest version) for configuration, diagnostics, etc.

Diagnostics & safety

Built-in diagnostics: sensor failure, short/open circuits, ambient temperature limits, corrosion detection of sensor leads, etc. Diagnostic status according to NAMUR NE 107. Also has safety ratings (SIL2, etc.).

Mounting & housings

Multiple mounting options: in a head (terminal head form B as per DIN EN 50446), DIN-rail, field housing (including explosion-proof housings). Optional display (TID10) for head version.

Approvals

Certified for hazardous areas (ATEX, IECEx, FM, CSA, etc.), marine applications, etc.

 

Performance & Technical Specs

  • Accuracy: For say Pt100 from -50 to +200 °C, error ≤ 0.1 K.
  • Measuring ranges: Very wide, depending on sensor type: RTDs up to about +850 °C; thermocouples up to higher depending on the type.
  • Power supply: Typical supply voltage ranges like 11-42 V DC for the head transmitter, etc. Slightly different in SIL mode or in hazardous area versions.
  • Response times: Depends on sensor type and wiring (2/3/4 wire etc.). For RTDs about ~0.9-1.3 s, for thermocouples ~0.8 s, plus any additional delays of the internal reference or second channel.

 

Applications / Use Cases

  • Processes requiring high availability and reliability, where sensor failure could cause downtime. The dual channel / redundancy helps here.
  • Environments with hazardous area requirements.
  • Situations where precise temperature measurement is critical (chemical plants, energy plants, marine, etc.).
  • Where diagnostic information is important: e.g. early detection of cable or sensor degradation, monitoring for safe operation.

 

Benefits

  • Increased safety & reduced risk (through diagnostics, sensor redundancy, safety approvals).
  • High stability & accuracy → better process control.
  • Flexibility in mounting and sensor type.
  • Lower maintenance & downtime, thanks to diagnostics and dual input options.

Envoyez votre demande directement à nous